The RAILIANCE-WP migration numbered from RPF-WP-0001 without checking whether the target prefix was already in use. It was: this repository already had RPF-WP records, and the migration collided at 0018, 0019 and 0020, putting two unrelated workplans on each identifier. Central was left holding mixed records — rpf-wp-0018 carried the status of one file and the backing path of the other, because the reset processed two files claiming one identifier. The three files the migration displaced move to 0025-0027; the pre-existing records keep their numbers. Projection UUIDs are re-derived. Refs STATE-WP-0083-T05 Assistant: claude-code Assistant-Model: opus Assistant-Process: 2583210@bnt-lap001 Assistant-Session: f2bff2d5-e9b2-4338-92ca-10282a927006
87 lines
3.1 KiB
Markdown
87 lines
3.1 KiB
Markdown
---
|
|
id: RPF-WP-0025
|
|
type: workplan
|
|
title: "Retract public OpenBao listener behind operator-only access"
|
|
domain: financials
|
|
repo: railiance-platform
|
|
status: blocked
|
|
owner: codex
|
|
topic_slug: railiance
|
|
created: "2026-08-23"
|
|
updated: "2026-08-23"
|
|
related:
|
|
- RMASTER-WP-0020-T09
|
|
- RAPP-OPENBAO-WP-0002
|
|
state_hub_workstream_id: "6dda6039-295e-5cac-aef6-3183c3218649"
|
|
---
|
|
|
|
# RPF-WP-0025 — OpenBao operator-only access
|
|
|
|
## Goal
|
|
|
|
Implement the S3-owner half of RMASTER-WP-0020-T09 without coupling it to
|
|
destructive CoulombCore cleanup.
|
|
|
|
## T01 — Align the retained compatibility source
|
|
|
|
```task
|
|
id: RPF-WP-0025-T01
|
|
status: done
|
|
priority: high
|
|
state_hub_task_id: "80f9638f-707f-5038-bc77-5962b535949e"
|
|
```
|
|
|
|
The retained platform manifest now matches the canonical package posture:
|
|
Deployment plus ClusterIP Service only. Ordinary deploy no longer applies the
|
|
public-only middleware. The old Ingress remains solely in an explicitly named
|
|
rollback artifact.
|
|
|
|
## T02 — Add guarded retraction and rollback
|
|
|
|
```task
|
|
id: RPF-WP-0025-T02
|
|
status: done
|
|
priority: high
|
|
state_hub_task_id: "685aba0f-2594-5b99-903a-8c9cd16f6539"
|
|
```
|
|
|
|
`scripts/openbao-public-listener-transition.sh` pins the cluster UID, verifies
|
|
source and runtime packet posture, requires a lifecycle-healthy named tunnel,
|
|
and gates live deletion on exact confirmation plus attended-login verification.
|
|
It deletes only the Ingress and provides an exact rollback path.
|
|
|
|
## T03 — Complete the attended operator cutover
|
|
|
|
```task
|
|
id: RPF-WP-0025-T03
|
|
status: wait
|
|
priority: high
|
|
state_hub_task_id: "8850d742-7cd7-5a1b-ba52-4dbc4bdeba7e"
|
|
```
|
|
|
|
KeyCape revision `d150be1` now admits exactly
|
|
`http://127.0.0.1:18200/ui/vault/auth/netkingdom/oidc/callback` in the
|
|
source-owned `openbao-admin` client and pins it in configuration tests. The
|
|
OpenBao `auth/netkingdom/role/platform-admin` role must still independently
|
|
admit that exact callback, and an attended MFA login must pass. The
|
|
host-namespace preflight already proves `openbao-ui-railiance01`
|
|
lifecycle-healthy and reaches the expected overlay. Then execute the guarded
|
|
retraction, coordinate public DNS withdrawal with railiance-infra, and return
|
|
non-secret acceptance evidence to Railiance Master.
|
|
|
|
Net Kingdom revision `61aeafe` additionally applied the exact KeyCape callback
|
|
live and proved the public authorization endpoint accepts it. Railiance
|
|
Platform now carries the silent, narrowly scoped
|
|
`scripts/openbao-apply-operator-loopback-callback.sh` owner command for the
|
|
governed `openbao-platform-admin-login` lane. The remaining hold is one
|
|
attended OIDC/MFA execution of that command followed by one loopback UI login.
|
|
|
|
An attended attempt on 2026-08-23 failed closed before command handoff. Warden
|
|
contained all login output and did not execute the role update; its cleanup
|
|
could not confirm self-revocation, so the attempt is terminal NO-GO and must
|
|
not be treated as callback evidence. No public-listener or OpenBao role change
|
|
was made. T03 remains `wait` for a fresh attended execution after the operator
|
|
is ready to complete the browser/MFA act.
|
|
|
|
This workplan authorizes no OpenBao seal/unseal, policy broadening, PVC or
|
|
Secret mutation, reboot, restore, or RMASTER-WP-0020-T08 cleanup.
|