In-repo journey, recovery, and security matrix are complete (150 tests). T03/T04 stay cancelled at coulomb-social and KeyCape. Production enablement remains an operator flag plus governed verification and SMTP credentials.
2.6 KiB
Configuration Boundaries
Standalone Mode
Standalone mode is for local development, tests, prototypes, and small single-service deployments.
Expected characteristics:
- local configuration file or environment variables;
- local database or file-backed persistence during early development;
- fixture or local identity claims adapter;
- deterministic authorization test adapter;
- no password, MFA, or token issuance responsibility inside user-engine.
Platform Mode
Platform mode is for a NetKingdom-aligned shared service deployment.
Expected characteristics:
- verified IAM Profile claims arrive from an identity layer;
- authorization decisions are requested through the authorization check port;
- runtime secrets are delivered through a scoped secret provider;
- audit records and outbox events are correlated with platform sinks;
- tenant and application bindings are explicit.
Secret Names
The code should refer to logical secret names, not platform paths. Concrete
secret lookup is owned by the active SecretProvider adapter.
Initial logical names:
database.urlevent.signing_keywebhook.shared_secret
Production Guardrails
- Local issuers must be rejected by production adapters.
- Sensitive writes must fail closed when authorization is unavailable.
- Claims enrichment must be optional and must not make user-engine a token issuer.
Portal integration settings
The production portal requires its existing database, OIDC, proxy-marker, and identity-provisioning settings. Platform tenant creation is enabled only when both of these settings are present:
USER_ENGINE_TENANT_MANAGEMENT_URL— tenant-authority base URL;USER_ENGINE_TENANT_MANAGEMENT_TOKEN— workload-scoped bearer token.
The adapter calls POST /v1/tenants with correlation and idempotency headers.
The token is never returned in errors, audit records, outbox events, or browser
responses. When the settings are absent, ordinary portal behavior remains
available and platform tenant creation fails closed as unavailable.
Public registration is off unless USER_ENGINE_PUBLIC_REGISTRATION=true.
Enabling it also requires the verification adapter and allow-lists:
USER_ENGINE_REGISTRATION_VERIFICATION_URLUSER_ENGINE_REGISTRATION_VERIFICATION_TOKENUSER_ENGINE_REGISTRATION_CLIENTSUSER_ENGINE_REGISTRATION_TENANTSUSER_ENGINE_REGISTRATION_PASSWORD_SETUP_ORIGINSUSER_ENGINE_MAIL_URLandUSER_ENGINE_MAIL_TOKENwhen verification mail is delivered through the outbox
The service fails closed when those settings are absent. Do not add a placeholder or reused credential to turn the flag on.